StaticLoad#
Static load group.
Common Parameters: u, name, idx, p0, q0, zone
Available models: PQ
PQ#
PQ load model.
TODO: implement type conversion in config
Parameters#
Name |
Symbol |
Description |
Default |
Unit |
Properties |
---|---|---|---|---|---|
idx |
unique device idx |
||||
u |
\(u\) |
connection status |
1 |
bool |
|
name |
device name |
||||
bus |
linked bus idx |
mandatory |
|||
Vn |
\(V_n\) |
AC voltage rating |
110 |
kV |
non_zero |
p0 |
\(p_0\) |
active power load in system base |
0 |
p.u. |
|
q0 |
\(q_0\) |
reactive power load in system base |
0 |
p.u. |
|
vmax |
\(v_{max}\) |
max voltage before switching to impedance |
1.200 |
||
vmin |
\(v_{min}\) |
min voltage before switching to impedance |
0.800 |
||
owner |
owner idx |
||||
zone |
Retrieved zone idx |
||||
ctrl |
\(c_{trl}\) |
load controllability |
1 |