DG#
Distributed generation (small-scale).
See ANDES Documentation SynGen here for the notes on replacing StaticGen and setting the power ratio parameters.
Reference:
[1] ANDES Documentation, SynGen, [Online]
Available:
https://docs.andes.app/en/latest/groupdoc/SynGen.html#syngen
Common Parameters: u, name, idx, bus, fn
PVD1#
Distributed PV model, revised from ANDES PVD1
model for
dispatch.
Following parameters are omitted from the original dynamic model:
fn
, busf
, xc
, pqflag
, igreg
, v0
, v1
,
dqdv
, fdbd
, ddn
, ialim
, vt0
, vt1
, vt2
,
vt3
, vrflag
, ft0
, ft1
, ft2
, ft3
, frflag
,
tip
, tiq
, recflag
.
Reference:
[1] ANDES Documentation, PVD1
Available:
https://docs.andes.app/en/latest/groupdoc/DG.html#pvd1
Parameters#
Name |
Symbol |
Description |
Default |
Unit |
Properties |
---|---|---|---|---|---|
idx |
unique device idx |
||||
u |
\(u\) |
connection status |
1 |
bool |
|
name |
device name |
||||
bus |
interface bus id (place holder) |
mandatory |
|||
gen |
static generator index |
mandatory |
|||
Sn |
\(S_n\) |
device MVA rating |
100 |
MVA |
|
gammap |
\(\gamma_p\) |
Ratio of ESD1.pref0 w.r.t to that of static PV |
1 |
||
gammaq |
\(\gamma_q\) |
Ratio of ESD1.qref0 w.r.t to that of static PV |
1 |
ESD1#
Distributed energy storage model, revised from ANDES ESD1
model for
dispatch.
Following parameters are omitted from the original dynamic model:
fn
, busf
, xc
, pqflag
, igreg
, v0
, v1
,
dqdv
, fdbd
, ddn
, ialim
, vt0
, vt1
, vt2
,
vt3
, vrflag
, ft0
, ft1
, ft2
, ft3
, frflag
,
tip
, tiq
, recflag
.
Reference:
[1] ANDES Documentation, ESD1
Available:
https://docs.andes.app/en/latest/groupdoc/DG.html#esd1
Parameters#
Name |
Symbol |
Description |
Default |
Unit |
Properties |
---|---|---|---|---|---|
idx |
unique device idx |
||||
u |
\(u\) |
connection status |
1 |
bool |
|
name |
device name |
||||
bus |
interface bus id (place holder) |
mandatory |
|||
gen |
static generator index |
mandatory |
|||
Sn |
\(S_n\) |
device MVA rating |
100 |
MVA |
|
gammap |
\(\gamma_p\) |
Ratio of ESD1.pref0 w.r.t to that of static PV |
1 |
||
gammaq |
\(\gamma_q\) |
Ratio of ESD1.qref0 w.r.t to that of static PV |
1 |
||
SOCmin |
\(SOC_{min}\) |
Minimum required value for SOC in limiter |
0 |
||
SOCmax |
\(SOC_{max}\) |
Maximum allowed value for SOC in limiter |
1 |
||
SOCinit |
\(SOC_{init}\) |
Initial state of charge |
0.500 |
||
En |
\(E_n\) |
Rated energy capacity |
100 |
MWh |
|
EtaC |
\(Eta_C\) |
Efficiency during charging |
1 |
||
EtaD |
\(Eta_D\) |
Efficiency during discharging |
1 |