StaticGen#

Generator group.

Notes#

For co-simulation with ANDES, check ANDES StaticGen for replacing static generators with dynamic generators.

Common Parameters: u, name, idx, Sn, Vn, p0, q0, ra, xs, subidx, bus, pmax, pmin, pg0, ctrl, R10

Common Variables: p, q

Available models: Slack, PV

Slack#

Slack generator model.

Parameters#

Name

Symbol

Description

Default

Unit

Properties

idx

unique device idx

u

\(u\)

connection status

1

bool

name

device name

Sn

\(S_n\)

Power rating

100

non_zero

Vn

\(V_n\)

AC voltage rating

110

non_zero

subidx

index for generators on the same bus

bus

idx of the installed bus

mandatory

busr

bus idx for remote voltage control

p0

\(p_0\)

active power set point in system base

0

p.u.

q0

\(q_0\)

reactive power set point in system base

0

p.u.

pmax

\(p_{max}\)

maximum active power in system base

999

p.u.

pmin

\(p_{min}\)

minimum active power in system base

-1

p.u.

qmax

\(q_{max}\)

maximim reactive power in system base

999

p.u.

qmin

\(q_{min}\)

minimum reactive power in system base

-999

p.u.

v0

\(v_0\)

voltage set point

1

vmax

\(v_{max}\)

maximum voltage voltage

1.400

vmin

\(v_{min}\)

minimum allowed voltage

0.600

ra

\(r_a\)

armature resistance

0

xs

\(x_s\)

armature reactance

0.300

wmod

\(w_{mod}\)

Machine ctrl. mode [PSS/E]

0

int

a0

\(\theta_0\)

reference angle set point

0

ctrl

\(c_{trl}\)

generator controllability

1

Pc1

\(P_{c1}\)

lower real power output of PQ capability curve

0

p.u.

Pc2

\(P_{c2}\)

upper real power output of PQ capability curve

0

p.u.

Qc1min

\(Q_{c1min}\)

minimum reactive power output at Pc1

0

p.u.

Qc1max

\(Q_{c1max}\)

maximum reactive power output at Pc1

0

p.u.

Qc2min

\(Q_{c2min}\)

minimum reactive power output at Pc2

0

p.u.

Qc2max

\(Q_{c2max}\)

maximum reactive power output at Pc2

0

p.u.

Ragc

\(R_{agc}\)

ramp rate for load following/AGC

999

p.u./h

R10

\(R_{10}\)

ramp rate for 10 minute reserves

999

p.u./h

R30

\(R_{30}\)

30 minute ramp rate

999

p.u./h

Rq

\(R_{q}\)

ramp rate for reactive power (2 sec timescale)

999

p.u./h

apf

\(a_{pf}\)

area participation factor

0

pg0

\(p_{g0}\)

active power start point (system base)

0

p.u.

td1

\(t_{d1}\)

minimum ON duration

0

h

td2

\(t_{d2}\)

minimum OFF duration

0

h

zone

Retrieved zone idx

Variables#

Name

Symbol

Type

Description

Unit

ud

\(u_d\)

Algeb

connection status decision

bool

p

\(p\)

Algeb

active power generation

p.u.

q

\(q\)

Algeb

reactive power generation

p.u.

PV#

PV generator model.

TODO: implement type conversion in config

Parameters#

Name

Symbol

Description

Default

Unit

Properties

idx

unique device idx

u

\(u\)

connection status

1

bool

name

device name

Sn

\(S_n\)

Power rating

100

non_zero

Vn

\(V_n\)

AC voltage rating

110

non_zero

subidx

index for generators on the same bus

bus

idx of the installed bus

mandatory

busr

bus idx for remote voltage control

p0

\(p_0\)

active power set point in system base

0

p.u.

q0

\(q_0\)

reactive power set point in system base

0

p.u.

pmax

\(p_{max}\)

maximum active power in system base

999

p.u.

pmin

\(p_{min}\)

minimum active power in system base

-1

p.u.

qmax

\(q_{max}\)

maximim reactive power in system base

999

p.u.

qmin

\(q_{min}\)

minimum reactive power in system base

-999

p.u.

v0

\(v_0\)

voltage set point

1

vmax

\(v_{max}\)

maximum voltage voltage

1.400

vmin

\(v_{min}\)

minimum allowed voltage

0.600

ra

\(r_a\)

armature resistance

0

xs

\(x_s\)

armature reactance

0.300

wmod

\(w_{mod}\)

Machine ctrl. mode [PSS/E]

0

int

ctrl

\(c_{trl}\)

generator controllability

1

Pc1

\(P_{c1}\)

lower real power output of PQ capability curve

0

p.u.

Pc2

\(P_{c2}\)

upper real power output of PQ capability curve

0

p.u.

Qc1min

\(Q_{c1min}\)

minimum reactive power output at Pc1

0

p.u.

Qc1max

\(Q_{c1max}\)

maximum reactive power output at Pc1

0

p.u.

Qc2min

\(Q_{c2min}\)

minimum reactive power output at Pc2

0

p.u.

Qc2max

\(Q_{c2max}\)

maximum reactive power output at Pc2

0

p.u.

Ragc

\(R_{agc}\)

ramp rate for load following/AGC

999

p.u./h

R10

\(R_{10}\)

ramp rate for 10 minute reserves

999

p.u./h

R30

\(R_{30}\)

30 minute ramp rate

999

p.u./h

Rq

\(R_{q}\)

ramp rate for reactive power (2 sec timescale)

999

p.u./h

apf

\(a_{pf}\)

area participation factor

0

pg0

\(p_{g0}\)

active power start point (system base)

0

p.u.

td1

\(t_{d1}\)

minimum ON duration

0

h

td2

\(t_{d2}\)

minimum OFF duration

0

h

zone

Retrieved zone idx

Variables#

Name

Symbol

Type

Description

Unit

ud

\(u_d\)

Algeb

connection status decision

bool

p

\(p\)

Algeb

active power generation

p.u.

q

\(q\)

Algeb

reactive power generation

p.u.